South Carolina S 116: Multi Family Dwellings
Status: Scrivener's error corrected (as of 2025-01-17)
State: South Carolina · Session: 2025-2026 · Bill: S 116
Sponsors: Adams
Bill Text
2025-2026 Bill 116 Text of Previous Version (Jan. 17, 2025) - South Carolina Legislature Online South Carolina General Assembly 126th Session, 2025-2026 Bill 116 Indicates Matter Stricken Indicates New Matter (Text matches printed bills. Document has been reformatted to meet World Wide Web specifications.) A bill TO AMEND THE SOUTH CAROLINA CODE OF LAWS SO AS TO ENACT THE "MULTIFAMILY DWELLING SAFETY ACT"; BY ADDING SECTION 20-21-110 SO AS TO PROVIDE DEFINITIONS FOR A MULTIFAMILY DWELLING AND OTHER TERMS; BY ADDING SECTION 20-21-120 SO AS TO DEFINE A QUALIFIED INSPECTOR OF MULTIFAMILY DWELLINGS; BY ADDING SECTION 20-21-130 SO AS TO REQUIRE THE DEPARTMENT OF LABOR, LICENSING AND REGULATION TO ADOPT A MULTIFAMILY DWELLING BALCONY CODE ESTABLISHING MINIMUM STANDARDS FOR BALCONY RAILINGS THAT ARE PRIMARILY CONSTRUCTED OF WOOD AND ARE LOCATED IN MULTIFAMILY DWELLINGS; BY ADDING SECTION 20-21-140 SO AS TO REQUIRE THE DEPARTMENT TO PERIODICALLY CONDUCT INSPECTIONS OF SUCH BALCONIES TO ASCERTAIN COMPLIANCE WITH THE CODE; BY ADDING SECTION 20-21-150 SO AS TO PROVIDE THAT THE DEPARTMENT SHALL CHARGE A PROPERTY OWNER A FEE FOR INSPECTIONS MADE TO ENFORCE THE MULTIFAMILY DWELLING BALCONY CODE; BY ADDING SECTION 20-21-160 SO AS TO PROVIDE REMEDIES FOR VIOLATIONS; BY ADDING SECTION 20-21-170 SO AS TO PROVIDE THAT THE DEPARTMENT MAY AUTHORIZE WAIVERS OR EXEMPTIONS UNDER THE MULTIFAMILY DWELLING BALCONY CODE; AND BY ADDING SECTION 20-21-180 SO AS TO PROVIDE PENALTIES FOR VIOLATION OF THE MULTIFAMILY DWELLING BALCONY CODE. Be it enacted by the General Assembly of the State of South Carolina: SECTION 1. This act may be cited as the "Multifamily Dwelling Safety Act". SECTION 2. Title 20 of the S.C. Code is amended by adding: CHAPTER 21 Multifamily Dwelling Safety Act Section 20-21-110. As used in this chapter: (1) "Department" means the Department of Labor, Licensing, and Regulation. (2) "Inspector" means a person employed by the department for the purpose of conducting balcony inspections in the administration of this chapter. (3) "Multifamily dwelling" means a property containing two or more dwelling units, including: (a) an apartment house; (b) a boarding house; (c) a convent; (d) a dormitory; (e) a fraternity or sorority house; (f) a hotel or motel; (g) a monastery; and (h) a vacation timeshare property. (4) "Multifamily dwelling" does not include a condominium or other property subject to the Horizontal Property Act. (5) "Special inspector" means an inspector licensed by the department but not employed by the department. Section 20-21-120. To be qualified to serve as an inspector or special inspector, a person must be: (1) a professional engineer licensed under Chapter 22 of this title and experienced in the practice of structural engineering; (2) an architect licensed under Chapter 3 of this title and knowledgeable in the design, construction, and inspection of buildings; or (3) for purposes of the inspection of a multifamily dwelling containing more than ten dwelling units, a qualified person with at least five years of experience in multifamily dwelling operations, upkeep, and maintenance as considered appropriate by the department. Section 20-21-130. (A) The department shall promulgate regulations adopting a Multifamily Dwelling Balcony Code to set minimum standards for balcony railings that are primarily constructed of wood and are located in multifamily dwellings. (B) The Multifamily Dwelling Balcony Code applies to residential structures used for human habitation, excluding owner occupied housing units and other housing exempted by the department through regulation. Section 20-21-140. (A) The department shall inspect balcony railings that are primarily constructed of wood in each multifamily dwelling that has such balcony railings at least once every five years, beginning no later than ten years after the balcony is constructed, to ensure that the balcony railings meet the requirements of the Multifamily Dwelling Balcony Code. The department shall conduct initial inspections of balcony railings in existence on the effective date of this chapter within five years after the effective date of this chapter. (B) In performing an inspection, the department may employ its own inspector or may authorize a special inspector to conduct the inspection on behalf of the department. (C) The department shall provide notice to the owner of a multifamily dwelling at least ten days before conducting an inspection. (D) An owner of a multifamily dwelling subject to regulation by this chapter shall grant access to the dwelling and all balconies in the dwelling to the department for the purpose of conducting inspections pursuant to the provisions of this chapter. Inspections must be permitted during normal business hours or as otherwise provided by the department. (E) If the department determines through a
View South Carolina S 116 on LegisTrack → — full text, sponsors, votes, campaign finance, and cross-state matches.