Florida HB 801: Air-Conditioning and Mechanical Contractors
Status: Died in Commerce Committee (as of 2025-06-16)
State: Florida · Session: 2025 · Bill: HB 801
Subjects: and solicitations, crimes, public health, real and personal property, regulation of professions and occupations
Sponsors: Albert, Industries & Professional Activities Subcommittee, Porras
Bill Text
CS/HB 801 2025 CODING: Words stricken are deletions; words underlined are additions. hb801-01-c1 Page 1 of 6 F L O R I D A H O U S E O F R E P R E S E N T A T I V E S A bill to be entitled 1 An act relating to air-conditioning and mechanical 2 contractors; amending s. 489.105, F.S.; revising the 3 definitions of the terms "class A air-conditioning 4 contractor" and "mechanical contractor" to include 5 additional services that such contractors may perform; 6 providing an effective date. 7 8 Be It Enacted by the Legislature of the State of Florida: 9 10 Section 1. Paragraphs (f) and (i) of subsection (3) of 11 section 489.105, Florida Statutes, are amended to read: 12 489.105 Definitions.—As used in this part: 13 (3) "Contractor" means the person who is qualified for, 14 and is only responsible for, the project contracted for and 15 means, except as exempted in this part, the person who, for 16 compensation, undertakes to, submits a bid to, or does himself 17 or herself or by others construct, repair, alter, remodel, add 18 to, demolish, subtract from, or improve any building or 19 structure, including related improvements to real estate, for 20 others or for resale to others; and whose job scope is 21 substantially similar to the job scope described in one of the 22 paragraphs of this subsection. For the purposes of regulation 23 under this part, the term "demolish" applies only to demolition 24 of steel tanks more than 50 feet in height; towers more than 50 25 CS/HB 801 2025 CODING: Words stricken are deletions; words underlined are additions. hb801-01-c1 Page 2 of 6 F L O R I D A H O U S E O F R E P R E S E N T A T I V E S feet in height; other structures more than 50 feet in height; 26 and all buildings or residences. Contractors are subdivided into 27 two divisions, Division I, consisting of those contractors 28 defined in paragraphs (a)-(c), and Division II, consisting of 29 those contractors defined in paragraphs (d)-(q): 30 (f) "Class A air-conditioning contractor" means a 31 contractor whose services are unlimited in the execution of 32 contracts requiring the experience, knowledge, and skill to: 33 1. Install, maintain, repair, fabricate, alter, extend, or 34 design, if not prohibited by law, central air-conditioning, 35 refrigeration, heating, and ventilating systems, including duct 36 work in connection with a complete system if such duct work is 37 performed by the contractor as necessary to complete an air-38 distribution system, boiler and unfired pressure vessel systems, 39 and all appurtenances, apparatus, or equipment used in 40 connection therewith, and any duct cleaning and equipment 41 sanitizing that requires at least a partial disassembling of the 42 system.; to 43 2. Install, maintain, repair, fabricate, alter, extend, or 44 design, if not prohibited by law, piping, insulation of pipes, 45 vessels and ducts, pressure and process piping, and pneumatic 46 control piping.; to 47 3. Replace, disconnect, or reconnect power wiring on the 48 line or load side of the dedicated existing electrical 49 disconnect switch on single phase electrical systems.; to 50 CS/HB 801 2025 CODING: Words stricken are deletions; words underlined are additions. hb801-01-c1 Page 3 of 6 F L O R I D A H O U S E O F R E P R E S E N T A T I V E S 4. Repair or replace power wiring, disconnects, breakers, 51 or fuses for dedicated HVAC circuits with proper use of a 52 circuit breaker lock.; to 53 5. Install, disconnect, and reconnect low voltage heating, 54 ventilating, and air-conditioning control wiring.; and to 55 6. Install a condensate drain from an air-conditioning 56 unit to an existing safe waste or other approved disposal other 57 than a direct connection to a sanitary system. 58 7. Replace and repair existing package pool heaters and 59 connect replacement package pool heaters to existing pool 60 piping. The replacement of an existing package pool heater must 61 use the same make and model as the existing package pool heater. 62 This includes maintaining the flow rate, connection points, and 63 heater specifications without modifications to existing pool 64 piping or system components. The replacement or repair of an 65 existing package pool heater does not include alterations to the 66 pool's hydraulic system, the addition of bypass valves, the 67 installation of new plumbing, the rerouting of pipes, any 68 changes to the pool's circulation system, or any other 69 modifications beyond what is necessary to disconnect and 70 reconnect the unit to the existing piping. 71 8. Perform The scope of work for such contractor also 72 includes any excavation work incidental to work performed in 73 subparagraphs 1.-7., but not thereto, but does not include any 74 work such as liquefied petroleum or natural gas fuel lines 75 CS/HB 801 2025 CODING: Words stricken are deletions; words underlined are additions. hb801-01-c1 Page 4 of 6 F L O R I D A H O U S E O F R E P R E S E N T A T I V E S within buildings, exc
View Florida HB 801 on LegisTrack → — full text, sponsors, votes, campaign finance, and cross-state matches.